12.3.1.7 Check commissioning
You can check whether the new DECT system and the assigned end devices have been activated. After successful commissioning, new data must appear in the lines of the corresponding DECT objects:
|
You may need to refresh the page in Swyx Control Center to see the changes.
|
1 Select Terminals | DECT.
2 Select the Tab DECT systems.
In the line of the corresponding DECT system, in the column
Type appears
D800.
3 Select the Tab DECT base stations.
In the rows of the created base stations the correct values appear in the columns
Device type and
Firmware version.
In the line of the master base station the column
Master is marked with a check mark.
4 Select the Tab Assigned handsets.
In the rows of the created handsets the correct values appear in the columns
Terminal type and
Firmware version.
The DECT handsets are assigned to all desired users.
The DECT system is activated and connected to SwyxServer. Users can make calls with their DECT handsets.
|
Make sure that the new firmware is fully downloaded before using the handsets.
|
|
Downloading the firmware on DECT 800 handsets can take 10 to 30 minutes, depending on the model. You can check the status of the firmware on the handset via the administration menu: (See To unlock the administration menu). Menu | Calls | Admin Menu | Centr. Management - No FDL (No firmware download) - No firmware is downloaded. - NN% - Firmware is being downloaded, NN% of the operation is finished.
|