The Global Configuration of SwyxServer Configuring SwyxServer global settings “RemoteConnector” Tab
 
“RemoteConnector” Tab
You can configure SwyxServer for Internet connections with the new generation Clients using this tab.
Enable Remote Access
If support for direct Internet connections to new generation clients is required, activate the checkbox.
Authentication server (FQDN or public IP)
Enter the public server address and the port in the respective fields, so that the new generation Clients can access SwyxServers via the Internet. In a standby scenario, the corresponding inputs must also be entered for the standby system.
The registered public address of the authentication service must be configured within the respective settings on the Client computers.
* 
If you use a different standard port and not 9101, it has to be explicitly input in the Client settings.
For further information please refer to chapter Connections to new generation clients.
RemoteConnector Server (FQDN or public IP)
Enter the public server address and the SwyxRemoteConnector server port in the respective fields. The standard ports for the SwyxRemoteConnector are 16203 or 57203.
In a standby scenario, the corresponding inputs must also be entered for the standby system.
For further information please refer to chapter Internet connection via SwyxRemoteConnector.
* 
In the SwyxWare administration on the standby server, you need not enter any settings on the “RemoteConnector” tab. The inputs on the master server are automatically applied.