Connection of a SwyxDECT 800 system Configuration of the SwyxDECT 800 Configuration in detail DECT 'DECT | Master' page
 
'DECT | Master' page
Please define which mode the station uses, Master or Slave. Enter the associated parameters.
A base station can work in various states (mode):
*Active
if this base station is a master base station
*Standby
if this base station is a Standby master base station
*Off
if this base station is a slave base station
*Deployment
needed only for coverage tests. Here the voice is forwarded directly from the handset back to the handset.
Activate "Enable Pari function".
IP PBX (Configuration of SwyxServer)
1. Select "SIP" as protocol and enter the IP address of the SwyxServer under "Proxy".
2. If you use SwyxWare standby, enter under "Alt. Proxy" the IP address of the standby SwyxServer.
3. Enter the maximum number of digits of an internal number in the SwyxWare (e.g. 3) in the field "Max. internal number length". This number length is used for deciding whether a call is from an internal or external source, in order e.g. to use the corresponding ring tone.
4. Activate the field "Enbloc Dialing".
If this optionis activated, all digits of the number can be entered before the handset is lifted. The phone number will be dialed completely (as a block) when the handset is lifted.
5. Deactivate the field "Enable Enbloc Send-key".
6. Deactivate the field "Allow DTMF through RTP".
7. Configure the "SIP Interoperability Settings":
The field "Registration time-to-live" can be left blank, and all checkboxes (e.g. "Hold before Transfer") should be deactivated. For "Hold Signaling", select the setting "sendonly".
If the device is configured as Standby Master (Mode=Standby), the following changes are also needed:
8. Enter the IP address of the master in the field "Primary Master IP Address".
9. After a change, start the base station again under 'Reset', so that the effect of the configuration changes can be seen.