Connection of a SwyxDECT 800 system Configuration of the SwyxDECT 800 Configuration in detail DECT Sync 'DECT Sync | Status' page
 
'DECT Sync | Status' page
This area only appears in the IPBS.
1. Select "DECT Sync | Status".
 
Field
Description
Sync off
Tuning of the running frequency for synchronization with the synch source.
Drift
Time difference between the current IPBS and its synch source.
Sync lost counter
A counter that increments, when IPBS stops the radio traffic for a while and subsequently re-starts the synchronization procedure.
RFPI
Radio Fixed Part Identity - ID of the synchronization bearer.
Carrier
The carrier frequency used for the air synchronization
Slot
Slot that is used for the synchronization.
Hop
Number of hops from the synchronization master to the synchronization bearer.
RSSI
Received Signal Strength Indication
FER
Frame Error Rate - a value between 0% and 100%. It should be below 80% for a synchronization to be possible.