Configuration of a slave base station
The initial configuration of a slave SwyxDECT 800 can be saved as a template and used for subsequent configurations of other slave base stations.
This is how you configure a slave base station
2. For a better identification, assign a unique device name under "General | Admin", which contains the location of the device, e.g. 'warehouse' or 'reception'.
5. As of version 3.2.2., a LDAP replication between master and slave is no longer necessary. The PARI service takes over this function.
In the field "Pari Master IP Address", enter the IP address of the Pari master (=DECT master) (
see 'DECT | Radio' page).
11. Under 'Reset', please start the base station again, so that the effect of the configuration changes can be seen.
12. Check whether the RGB LED is glowing blue (synchronization OK).
If after a minute it is still blinking red, it cannot synchronize with the master base station.
How to configure the remaining base stations
1. Define the address for the base station.
2. Call the web interface of the base station in the web browser.
3. Choose "Update | Config" and use the "Browse" button to select the base station created as a template.
4. Click on "Upload".
6. Under 'Reset', please start the base station again, so that the effect of the configuration changes can be seen.
7. Repeat steps
(1) to
(6) for the configuration of all further slave base stations.